[HOME] [Stock List] [Salesman] [Technical Index]
AIR HEATERS: [Air Heater] [Alternate Style] [Maximum Flow] [Pure Flow] [Standard Tee Type]
[Temp.Sensing]

HEATERS FOR EVERY APPLICATION
PHONE: (978) 777-0070
![]()
Air Process Heaters: Heavy Duty-Horizontal use
only

![]() |
|
Construction
Features
Specifications
| Maximum Amperage: 30 | |
| Cross Sectional Flow Area: .69 sq. in. | |
CFM |
Max.Watts/linear in. |
| 1 | 150 |
| 2 | 150 |
| 4 | 150 |
| 6 | 150 |
| 8 | 150 |
| 10 | 150 |
| 15 | 200 |
| 20 | 250 |
| 25 | 300 |
| 30 | 350 |
| 35 | 400 |
| 40 | 475 |
| 45 | 525 |
| 50 | 575 |
| 55 | 625 |
Pressure Rating: 100 psig
Pressure Drop vs. Air Flow
Pressure |
![]() Air Flow (SCFM) |
Size
Lengths are available from 6" - 36". Standard entry is 1/2"
NPT female and the standard exit is 1" NPT female.
| Length | Heated Length | Catalog No. |
| 6" | 3 1/2" | HA2-6 |
| 8" | 5 1/2" | HA2-8 |
| 10" | 7 1/2" | HA2-10 |
| 12" | 9 1/2" | HA2-12 |
| 18" | 15 1/2" | HA2-18 |
| 24" | 21 1/2" | HA2-24 |
Special Features Available
SF-28: Three phase
SF-29: Multiple heat circuits - Specify wattages.
SF-32: High voltage.
Consult factory for:
Lengths longer than those listed.
Current ratings above 30 amps.
[HOME] [Stock List] [Salesman] [Technical Index]
AIR HEATERS: [Air Heater] [Alternate Style] [Maximum Flow] [Pure Flow] [Standard Tee Type]
[Temp.Sensing]
We can be reached by e-mail at sales@hotwatt.com
When ordering catalogs please include your
phone number and
mailing address.