[HOME] [Stock List] [Salesman] [Technical Index]
AIR HEATERS: [Air Heater] [Alternate Style] [Heavy Duty] [Maximum Flow] [Pure Flow] [Temperature Sensing]
Standard Tee Type Air Heater: [3/8"] [1/2"] [3/4"] [1 1/4"]

HEATERS FOR EVERY APPLICATION
PHONE: (978) 777-0070
![]()
Air Process Heaters: 5/8" Diameter
Horizontal use only

Construction
Specifications
| Maximum Amperage: 15 | |
| Cross Sectional Flow Area: .072 sq. in. | |
| Maximum CFM: 15 | |
CFM |
Max.Watts/linear in. |
| 1 | 100 |
| 2 | 100 |
| 4 | 100 |
| 6 | 150 |
| 8 | 200 |
| 10 | 250 |
| 15 | 375 |
Pressure Drop vs. Air Flow
Pressure |
![]() Air Flow (SCFM) |
Sizes
| Diameter: 5/8" | |||
| Length | Heated Length | Cat. No. w/o fittings |
Cat. No. w/male NPT fitings |
| 3" | 2 1/2" | AH62-3 | AH62-3-MF |
| 4" | 3 1/2" | AH62-4 | AH62-4-MF |
| 5" | 4 1/2" | AH62-5 | AH62-5-MF |
| 6" | 5 1/2" | AH62-6 | AH62-6-MF |
| 7" | 6 1/2" | AH62-7 | AH62-7-MF |
| 8" | 7 1/2" | AH62-8 | AH62-8-MF |
| 9" | 8 1/2" | AH62-9 | AH62-9-MF |
| 10" | 9 1/2" | AH62-10 | AH62-10-MF |
| 12" | 11 1/2" | AH62-12 | AH62-12-MF |
Special Features Available
MF: 1/2" NPT male fittings (add MF to catalog number).
FF: 1/4" NPT female fittings (add FF to catalog number).
HF: Hose adaptor on entry end only (add HF to catalog number and
specify I.D. of hose).
SF-28: Three Phase
SF-29: Multiple Heat circuits - Specify wattages
[HOME] [Stock List] [Salesman] [Technical Index]
AIR HEATERS: [Air Heater] [Alternate Style] [Heavy Duty] [Maximum Flow] [Pure Flow] [Temperature Sensing]
Standard Tee Type Air Heater: [3/8"] [1/2"] [3/4"] [1 1/4"]
We can be reached by e-mail at sales@hotwatt.com
When ordering catalogs please include your
phone number and
mailing address.