[HOME]
[Stock List]
[Salesman]
[Technical
Index]
GLASROPE HEATERS: [Glasropes] [Tubular Sheathed Glasrope]

HEATERS FOR EVERY APPLICATION
PHONE: (978) 777-0070
![]()
Foil Heaters

U.L. Recognized - E48358 C.S.A. Certified - 016386-0-000
Applications
Battery Warmers, Cabinets, Defrost Applications, Heated Food Tables, Laboratory Equipment,
Incubators, Ceiling Panels, and Wall Panels.
Features
Wattage
The maximum wattage is based on 3 watts per square inch of surface.
Voltage
Voltage is normally 120 or 240 volts. Lower voltages are available.
Construction
Foil Heater Constructions
Type A:
Type B:
Mechanically Fastened: Flexible
Type C:
Mechanically Fastened: Semi-Rigid.
Standard Terminations
SF1: Flexible leads for applications where leads can be bent close
to the end of the unit.
Leads are non-repairable.
![]()
Special Features
SF11A: Ring terminals. Specify size: #6, #8, #10.
![]()
SF11B: Straight quick connect terminals. Specify male or female and
size: 3/16" or 1/4".
![]()
SF11C: Flag quick connect terminals. Specify male or female and
size: 3/16" or 1/4".

SF11D: Spade terminals. Specify size: #6, #8, #10.
![]()
How to Order
Determine catalog number as shown below. For complex configurations,
attach drawings.
Example: FH3-6/50W/120V/SF1-12/SF11A-#8/A4-20
FH: Prefix for foil heater
3: Width of heater from which side the lead comes out
6: Length of heater
50W: Wattage
120V: Voltage
SF1-12: Lead type and length
SF11A: Terminal if required
A: Construction of heater (specify A, B, C)
4: The number of passes of element inside the foil (generally
determined by the factory)
20: Element length (generally determined by the factory)