Strip heaters:
  Ceramic Insulated

High Temperature Strip Heater

U.L. Recognized  -  E56973           C.S.A. Certified  -   016386-0-000


Applications
Dies, Molds, Plastic Forming and Sealing, Tank and Kettle Heating.
For specific applications, correctly rated elements should be used to prevent
overheating and to ensure long life. A guide to correct watt densities for
specific applications is shown below.

Features


Construction  

Construction                  

  1. Seamless stainless steel sheath.
  2. Post terminals.
  3. Ceramic element support.
  4. Element wire situated in close proximity to outside surface for maximum heat transfer
    and minimum internal temperature while preserving good dielectric qualities.
  5. Magnesium oxide packing.

Strip heaters:  Ceramic Insulated

 

Strip heaters:  Ceramic Insulated                  

 

Catalog
Number
"A" "B" "C" Min.
Watts
Max.
Watts
CS-5.5 5 1/2" 4 1/2" 1" 50 180
CS-7.5 7 1/2" 6 1/2" 3" 50 360
CS-8 8" 7" 2 3/4" 50 430
CS-9.5 9 1/2" 8 1/2" 4 1/4" 50 510
CS-10.5 10 1/2" 9 1/2" 5 1/4" 50 630
CS-12 12" 11" 7 1/4" 50 810
CS-14 14" 13" 9 1/4" 50 1050
CS-15.2 15 1/4" 14 1/4" 10" 50 1200
CS-16.2 16 1/4" 15 1/4" 11" 50 1320
CS-18 18" 17" 12 3/4" 50 1530
CS-19.5 19 1/2" 18 1/2" 14 1/4" 50 1710
CS-21 21" 20" 15 3/4" 50 1890
CS-23.7 23 3/4" 22 3/4" 18 1/2" 50 2220
CS-25.5 25 1/2" 24 1/2" 20 1/4" 50 2430
CS-26.7 26 3/4" 25 3/4" 21 1/2" 50 2580
CS-28.2

28 1/4"

27 1/4" 23" 75 2760
CS-30

30"

29" 24 3/4" 75 2970
CS-30.5 30 1/2" 29 1/2" 25 1/4" 75 3030
CS-33.5 33 1/2" 32 1/2" 28 1/4" 75 3390
CS-35.7 35 3/4" 34 3/4" 30 1/2" 75 3660
CS-38.5 38 1/2" 37 1/2" 33 1/4" 100 3990
CS-42.5 42 1/2" 41 1/2" 37 1/4" 100 4320
CS-47.7 47 3/4" 46 3/4" 42 1/2" 100 4320
CS-50.5 50 1/2" 49 1/4" 45 1/4" 100 4320
CS-53.7 53 3/4" 52 3/4" 48 1/2" 100 4320
CS-63.7

63 3/4"

62 3/4" 58 1/2" 100 4320


Standard Termination

Type OF:  Offset at one end.

Type OF: Offset at one end

Application Max.Watts/sq.in.
Water heating 40
Low viscosity liquid heating 16
Light oil heating 10 - 12.5
Heavy oil heating 6.25 - 10
Semi solid heating 5 - 6.25
Platen heating
Up to 300°F
300° - 600°F
600° - 800°F
40
40
20
15


Formula for Determination of Watt Density

Watts/sq.in. =              Total unit wattage             
                                  C (heated length) x 3


Optional Terminations

Type SSA:  Parallel at one end.  Heated length ("C") is 3/4" longer.

Type SSA: Parallel at one end

 
Type SO:  One each end.  Heated length ("C") is 1" shorter

     Type SO: One each end


Type SF1:  Flexible high temperature insulated leads. Specify length. Opposite end of unit may
be standard closure with mounting hole or any of the optional closures. (Blunt end, XS54, shown)
Suitable for use to 480V. Lead end may be sealed for moisture resistance.

       Type SF1: Flexible high temperature insulated leads
 

Optional End Closures
XS-54:
Blunt end. Welded each end with no mounting holes. May be used with
Type OF, SSA, or SO terminals. Heated length ("C") is 3" longer.

XS-54: Blunt end

 

XS-83: Short crimp. At each end with no mounting holes. May be used with
Type OF, SSA, or SO terminals. Heated length ("C") is 1" longer.

               XS-83: Short crimp



XS-84:
  Secondary insulating bushings. Required when units are connected in series
on voltages above 300V. Sheath must be isolated. Requires enlarged (1/2"  x  3/4")
mounting hole each end. May be used with Type OF, SSA, or SO terminals.

     XS-84: Secondary insulating bushings
Tolerances
Width:
  1.500, ±.010
Length:  Up to 24", ±1/16"
               24" and over,  ±1/8"
Thickness: .375, ±.005
Wattage tolerances are held to +5%, -10% at rated voltage.

Voltage
Standard voltages are either 120V or 240V. Other voltages are available.

How To Order
After determining the wattage required and the line voltage available, determine
the physical space available for heaters and the number of heaters required.
Review Stock List for In-Stock items.
Specify:  catalog number, wattage, voltage, termination, and special
features if required.
Example:  CS12/250W/120V/OF/XS54

[ HOME ]    [ Stock List ]    [ Stock Modifications ]    [ Salesman ]    [ Manufactured List ]    [Technical Index ]   

[ Air ]    [Band ]    [Ceramic ]     [Crankcase]    [ Foil ]    [Glasrope]    [Tubular/Tubular Immersion ]     [ Miscellaneous

Cartridge:
  [ Standard Cartridge ]  [ Immersion   ]  [  Metric ]  [ Square/Rectangular ]  [ Superwatt High Watt ]

Strip Heaters:      [ Strip ]    [ Ceramic Ins.Finned Strip ]    Strip Special Features ]

HH01580A.gif (1311 bytes)

We can be reached by e-mail at sales@hotwatt.com
When ordering catalogs please include your
phone number and mailing address.