Strip and Finned Strip Heaters

STRIPMICA.PNG (13834 bytes)

CERAMICINSULATEDFINNED.PNG (11591 bytes)

SPECIALFEATURES.PNG (2795 bytes)

STRIP&FINNEDSTRIPCATALOG.PNG (6151 bytes)

Strip heaters: Ceramic Insulated

STRIPCERAMIC.gif (297568 bytes)

STRIP&FINNEDSTRIPCATALOG.PNG (6151 bytes)

U.L. Recognized  -  E56973   
C.S.A. Certified  -   016386-0-000


Strip Heaters:
In-Stock
Finned Strip Heaters: In-Stock


Applications
Dies, Molds, Plastic Forming and Sealing, Tank and Kettle Heating. For specific applications, correctly
rated elements should be used to prevent overheating and to ensure long life. A guide to correct watt densities for specific applications is shown below.

Features

  • The Hotwatt Stainless Steel Strip Heater provides clean, dependable heat with sheath temperatures up to 1200F and watt densities up to 40 watts per square inch.

  • Because of the seamless stainless steel sheath, Hotwatt Ceramic Insulated Strip Heaters are dimensionally stable in milled slots.

  • Made in U.S.A


Construction  

  stripconstruction.PNG (128602 bytes)                

  1. Seamless stainless steel sheath.

  2. Post terminals.

  3. Ceramic element support.

  4. Element wire situated in close proximity to outside surface for maximum heat transfer and minimum internal temperature while preserving good dielectric qualities.

  5. Magnesium oxide packing.

stripconstruction2.PNG (85499 bytes)

 

 

 

 

 

 

 

stripconstruction3.PNG (31085 bytes)

 

 

                  

Catalog
Number
"A" "B" "C" Min.
Watts
Max.
Watts
CS-5.5 5 1/2" 4 1/2" 1" 50 180
CS-7.5 7 1/2" 6 1/2" 3" 50 360
CS-8 8" 7" 2 3/4" 50 430
CS-9.5 9 1/2" 8 1/2" 4 1/4" 50 510
CS-10.5 10 1/2" 9 1/2" 5 1/4" 50 630
CS-12 12" 11" 7 1/4" 50 810
CS-14 14" 13" 9 1/4" 50 1050
CS-15.2 15 1/4" 14 1/4" 10" 50 1200
CS-16.2 16 1/4" 15 1/4" 11" 50 1320
CS-18 18" 17" 12 3/4" 50 1530
CS-19.5 19 1/2" 18 1/2" 14 1/4" 50 1710
CS-21 21" 20" 15 3/4" 50 1890
CS-23.7 23 3/4" 22 3/4" 18 1/2" 50 2220
CS-25.5 25 1/2" 24 1/2" 20 1/4" 50 2430
CS-26.7 26 3/4" 25 3/4" 21 1/2" 50 2580
CS-28.2

28 1/4"

27 1/4" 23" 75 2760
CS-30

30"

29" 24 3/4" 75 2970
CS-30.5 30 1/2" 29 1/2" 25 1/4" 75 3030
CS-33.5 33 1/2" 32 1/2" 28 1/4" 75 3390
CS-35.7 35 3/4" 34 3/4" 30 1/2" 75 3660
CS-38.5 38 1/2" 37 1/2" 33 1/4" 100 3990
CS-42.5 42 1/2" 41 1/2" 37 1/4" 100 4320
CS-47.7 47 3/4" 46 3/4" 42 1/2" 100 4320
CS-50.5 50 1/2" 49 1/4" 45 1/4" 100 4320
CS-53.7 53 3/4" 52 3/4" 48 1/2" 100 4320
CS-63.7

63 3/4"

62 3/4" 58 1/2" 100 4320
  • Maximum wattage limited by 18 amp maximum at 240 volts for catalog numbers CS-42.5
    and longer. Any wattage is available between minimum and maximum without effecting price.

  • Unit lengths between and longer than those listed may be ordered.

  • Red catalog number denotes stock item. See stock section for specific ratings.

  • Standard termination is Type OF. Units under 8" long, standard termination is Type SSA.


Standard Termination

Type OF:  Offset at one end.

stripconstruction4.PNG (67271 bytes)

 

 

 

 

 

 

Application Max.Watts/sq.in.

Platen heating
Up to 300F
300 - 600F
600 - 800F

40
40
20
15


Formula for Determination of Watt Density

Watts/sq.in. =              Total unit wattage             
                                  C (heated length) x 3


Optional Terminations

Type SSA:  Parallel at one end.  Heated length ("C") is 3/4" longer.


stripcon.PNG (63441 bytes)

 

 

 

 

 

Type SO:  One each end.  Heated length ("C") is 1" shorter

     stripconstruction6.PNG (58655 bytes)


 

 

 

 

Type SF1:  Flexible high temperature insulated leads. Specify length. Opposite end of unit may
be standard closure with mounting hole or any of the optional closures. (Blunt end, XS54, shown)
Suitable for use to 480V. Lead end may be sealed for moisture resistance.

      
stripconstruction7.PNG (72288 bytes) 

 

 

 

 

Optional End Closures
XS-54:
Blunt end. Welded each end with no mounting holes. May be used with
Type OF, SSA, or SO terminals. Heated length ("C") is 3" longer.

strip8.PNG (58802 bytes)

 

 

 

 

 

 

XS-83: Short crimp. At each end with no mounting holes. May be used with
Type OF, SSA, or SO terminals. Heated length ("C") is 1" longer.

              

stripconstruction9.PNG (68490 bytes)

 

 

 

 

XS-84:  Secondary insulating bushings. Required when units are connected in series
on voltages above 300V. Sheath must be isolated. Requires enlarged (1/2"  x  3/4")
mounting hole each end. May be used with Type OF, SSA, or SO terminals.

    
stripconstruction10.PNG (53712 bytes)

 

 

 

 

 

 

Tolerances
Width:
  1.500, .010
Length:  Up to 24", 1/16"
               24" and over,  1/8"
Thickness: .375, .005
Wattage tolerances are held to +5%, -10% at rated voltage.

Voltage
Standard voltages are either 120V or 240V. Other voltages are available.

How To Order
After determining the wattage required and the line voltage available, determine
the physical space available for heaters and the number of heaters required.
Review Strip Heaters In-Stock.
Specify:  catalog number, wattage, voltage, termination, and special
features if required.
Example:  CS12/250W/120V/OF/XS54