[ HOME ]    [ Stock List ]    [ Stock Modifications ]    [ Salesman ]    [ Manufactured List ]    [Technical Index ]   

[ Accessories ]    [ Air ]    [  Band  ]    [  Drum  ]    [ Finned Strip ]     [ Strip ]

Voltage Control  ]    [  Temperature Indicating  ]

Standard and Superwatt Cartridge:   [ 1/8" ]    [ 1/4" ]    [ 3/8" ]    [ 1/2" ]    [ 5/8" ]    [ 3/4" ]    [ Immersion


 The Electric Heater Specialists
  HEATERS FOR EVERY APPLICATION
                                                                                                                                   PHONE: (978) 777-0070 X255
wpe1.jpg (1736 bytes)


In Stock:  Temperature Controlling Devices

Magnetic Contactors

Magnetic Contactors Catalog Number Amp.Rating Per Pole    Number Poles   Coil Voltage
30D030-1 30 3 120
30D030-2 30 3 240
30E030-1 40 3 120
30E030-2 40 3 240

Features
Magnetic Contactors are used to handle loads which exceed power handling capabilities
of line voltage thermostats.  Heavy duty copper contacts carry heavy duty currents at line
voltages.   Holding coils are rated for line voltage but can be furnished for other voltages
when specified.


Snap-Action Thermostats
   Bulb and Capillary

    
 
Snap-Action Thermostats

 Features

Catalog Number: AC602021HOT1

 

SURFACE MOUNT THERMOSTAT

Surface Mount Thermostat Catalog Number Range    Approx. °F/Full Turn Adj. Screw
30000-0 50 ° to 300°F 250°F
30000-48 85°  to 250°F 175°F
30002-0 50°  to 600°F 575°F

Features


CARTRIDGE THERMOSTAT

Cartridge Thermostat Catalog Number Sheath Material Range Approx. °F/Full Turn Adj. Screw
17000-0 Brass -100° to 400°F 90°F
17002-0 St. Steel -100° to 600°F 110°F

Features


HEX HEAD

Hex Head Catalog Number Shell and Head Range
17100-0 5/8" x 4 9/32"
All Brass
-100° to 400°F
17102-0 St. St. Shell
Brass Head
-100° to 600°F


FLANGE HEAD

Flange Head Catalog Number Shell and Head Range
17300-0 5/8" x 4 9/32"
All Brass
-100° to 400°F
17302-0 St. St. Shell
Brass Head
-100° to 600°F


COUPLING HEAD

Coupling Head Catalog Number Shell and Head Range
18000-0 5/8" x 4 21/32"
All Brass
-100° to 400°F
18002-0 St. St. Shell
Brass Head
-100° to 600°F

 
Series 100, Sub-Panel-Thermocouple Temperature Controller

Series 100 Description
The Series 100 controller was designed for general purpose commercial and industrial temperature regulating applications.  The latest solid state technology and an innovative modular packaging concept has produced a uniquely flexible family of controllers.  Low cost, a choice of many standard features and fast delivery make this series of controllers equally attractive to both the OEM and the end users.

Features

Specifications

How to Order
Specify catalog numbers as follows:
     - 10 Amp Triac        Cat. No. AC100 - 2A040 - JT03
     - 28 VDC output     Cat. No. AC100 - 2A090 - JT03
        to drive SSR


Series 120R, Panel Mounting,
Solid State Temperature Controller

Series 120R Description
The Series 120R Controller is an economical alternative to the fluid filled (bulb and capillary) type thermostat for any application which could benefit from the improved performance and reliability of an electronic temperature control.  Its compact, completely enclosed construction with industry standard mounting, integral setpoint pot, high current output capability and wide variety of sensor configurations, make this controller an ideal choice to replace mechanical thermostats in  many industrial and commercial applications.

Features

Advantages Over Bulb & Cap Thermostat

Specifications

How to Order

Specify catalog number as follows:  AC120R-D38-JT02

 

Digital Indicating Temperature Controller
Model 16A 2123, Mini 1/16 DIN Thermocouple Sensing

Model 16A 2123     Specifications
   
 
Selectable Inputs:   Thermocouple, RTD, DC Voltage, or
                                         DC Current selectable
        Input Impedance:   Thermocouple = 3 megohms minimum.
                                        Current = 10 ohms
                                        RTD current = 200uA
                                                                               Voltage = 5000ohms

Sensor Break Protection:  User determines control output to protect system
                                            after customer set time.
Display: Two 4 digit, 7 segment 0.30" high LEDs
Control Action:  Reverse (usually heating),
                           Direct (usually cooling) selectable
Proportional Band:  1 to 9999 °F, °C, or counts
Reset Time (Integral):  Off or 0.1 to 99.9 minutes
Rate Time (Derivative):  Off or 0.01 to 99.9 minutes
Cycle Rate:  1 to 80 seconds
On-Off Differential:  Adjustable 1° F, 1° C, or 1 count to full scale
                                   in 1° F, 1° C, or 1 count steps
Alarm On-Off Differential:  1° F, 1° C, or 1 count
Accuracy:  ±0.25% of span, ±1 least significant digit
Supply Voltage:  100 to 240 VAC, nominal., +10-15%, 50 to 400 Hz.
                             single phase; 132 to 240 VDC, nominal., +10-20%.
Power Consumption:  5VA maximum
Operating Temperature:  -10 to +55° C (+14 to 131° F)
Storage Temperature:  -40 to +80° C (-40 to 176° F)
Control Output Ratings:
     Relay: 
SPDT, 3A @ 240 VAC resistive; 1.5 A @ 240 VAC inductive;
                  Pilot Duty Rating: 250 VA 2 A @ 120 VAC or 1 A @ 240 VAC
     Alarm Relay:  SPST, 3 A @ 240 VAC resistive;
                  1.5 A @ 240 VAC inductive; Pilot Duty Rating: 240
                  VA, 2 A @ 120 VAC or 1A @ 240 VAC
     Switched Voltage (isolated):  15 VDC @ 20 mA
Panel Cutout:  45 mm x 45mm (1.775" x 1.775")
Depth Behind Mounting Surface:  115.3mm (4.54")
Weight:  227 g (8 oz)
Front Panel Rating:  Type 4X, (IP65)

How To Order

To Order, specify part number

            Model  16 A             2                      1                       2                       3
                                              |                        |                        |                        |
                                         Features         Alarm             Output A         Output B
                                
  2 = Standard        1 = Yes       2 = 15VDC         3 = Relay
                                                      
                               

SOLID STATE RELAYS

Solid State Relays How To Order   -  Specify Catalog Number per table below
Line Volts Max. Load Current Catalog Number
24-330 VAC 25 Amps AC-D1225

Features

THERMOCOUPLE PROBES

Features


3/16" Dia. Cartridge Type

3/16" Dia. Cartridge Type
Fiberglass insulated thermocouple wire .065 max. dia.
Temp Range Catalog No. ISA Type

0° F to 1200° F

AC HT-111206-001 J

For compression fittings, consult factory.


Coupling Head Type

Coupling Head Type
Fiberglass insulated thermocouple wire .065 max. dia.
Temp Range Catalog No. ISA Type

0° F to 1200° F

AC HT-121202-001 J


[ HOME ]    [ Stock List ]    [ Stock Modifications ]    [ Salesman ]    [ Manufactured List ]    [Technical Index ]   

[ Accessories ]    [ Air ]    [  Band  ]    [  Drum  ]    [ Finned Strip ]     [ Strip ]

Voltage Control  ]    [  Temperature Indicating  ]

Standard and Superwatt Cartridge:   [ 1/8" ]    [ 1/4" ]    [ 3/8" ]    [ 1/2" ]    [ 5/8" ]    [ 3/4" ]    [ Immersion

HH01580A.gif (1311 bytes)

We can be reached by e-mail at sales@hotwatt.com
When ordering catalogs please include your
phone number and mailing address.